MODEL | S-15-5 | S-15-12 | S-15-24 |
OUTPUT | DC VOLTAGE |
5V |
12V |
24V |
RATED CURRENT |
3A |
1.3A |
0.7A |
CURRENT RANGE |
0 ~ 3A |
0 ~ 1.3A |
0 ~ 0.7A |
RATED POWER |
15W |
15.6W |
16.8W |
RIPPLE & NOISE (max.) Note.2 |
50mVp-p |
50mVp-p |
100mVp-p |
VOLTAGE ADJ. RANGE |
4.75 ~ 5.5V |
10.8 ~ 13.2V |
21.6 ~ 26.4V |
VOLTAGE TOLERANCE Note.3 |
±2.0% |
±1.0% |
±1.0% |
LINE REGULATION |
±0.5% |
±0.5% |
±0.5% |
LOAD REGULATION |
±1.0% |
±0.5% |
±0.5% |
SETUP, RISE, HOLD TIME |
200ms, 100ms, 30ms at full load |
INPUT | VOLTAGE RANGE |
85 ~ 132VAC / 170 ~ 264VAC selected by switch 240 ~ 370VDC |
FREQUENCY RANGE |
47 ~ 63Hz |
EFFICIENCY (Typ.) |
65% |
68% |
72% |
AC CURRENT |
0.5A/115VAC 0.25A/230VAC |
INRUSH CURRENT (max.) |
COLD START 15A/115VAC 30A/230VAC |
LEAKAGE CURRENT |
<0.5mA/240VAC |
PROTECTION | OVERLOAD |
105 ~ 135% rated output power |
Protection type: Constant current limiting, recovers automatically after fault condition is reoved |
ENVIRONMENT | WORKING TEMP. |
-10 ~ +60ºC (Refer to output load derating curve) |
WORKING HUMIDITY |
20 ~ 90% RH non-condensing |
STORAGE TEMP., HUMIDITY |
-20 ~ +85ºC, 10 ~ 95% RH |
TEMP. COEFFICIENT |
±0.02%/ºC (0 ~ 50ºC) |
VIBRATION |
10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes |
SAFETY & EMC | SAFETY STANDARDS |
Design refer to UL1012 |
WITHSTAND VOLTAGE |
I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC |
ISOLATION RESISTANCE |
I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC |
EMI CONDUCTION & RADIATION |
Design refer to FCC Part15 J Conduction Class B |
OTHERS | MTBF |
522.1K hrs min. MIL-HDBK-217F (25ºC) |
DIMENSION |
99*97*36mm (L*W*H) |
PACKING |
0.30Kg; 60pcs/19.84Kg/0.0326CBM |
NOTE |
1.All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25ºC of ambient temperature. 2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3.Tolerance: includes set up tolerance, line regulation and load regulation. |