Home > Buy Now > Power Supplies > Switching Power Supply > 100W DC To DC Converter Power Supply
 


Power Supply Electrical Co.,Ltd
 
icon Products
icon Solar System

line

icon Company Profile

line

 
Contact us
Power Supply Electrical Co.,Ltd
[China]
Address:
YueQing Luishi Wenzhou Zhejiang China
Phone:
86-0057-62768170
Contact name:
Tony , powersupply.manufactory@gmail.




Power Supply Electrical Co.,Ltd


 
Products

100W DC To DC Converter Power Supply

Facebook   Twitter   Delicious   Google   My EC21   Email this page   Report Item Inquire now
100W DC To DC Converter  Power Supply

Click to enlarge image


 DC To DC Converter  Power Supply
100W DC-DC Converter Features:
2:1 wide input range
Protections: Short circuit/Over load/Over voltage
1500VDC I/O isolation
Built-in EMI filter, low ripple noise
100% full load burn-in test
Fixed switching frequency at 83KHz
24V and 48V input voltage design refer to LVD
Low cost
High reliability
SPECIFICATION:
MODELSD-100B-05SD-100C-05SD-100D-05SD-100B-12SD-100C-12SD-100D-12SD-100B-24SD-100C-24SD-100D-24
OUTPUTDC VOLTAGE 5V 12V 24V
RATED CURRENT 20A 8.5A 4.2A
CURRENT RANGE 0 ~ 20A 0 ~ 8.5A 0 ~ 4.2A
RATED POWER 100W 102W 100.8W
RIPPLE & NOISE (max.) Note.2 100mVp-p 120mVp-p 150mVp-p
VOLTAGE ADJ. RANGE 4.5 ~ 5.5VDC 11 ~ 16VDC 23 ~ 30VDC
VOLTAGE TOLERANCE Note.3 ±2.0% ±1.0% ±1.0%
LINE REGULATION ±0.5% ±0.3% ±0.2%
LOAD REGULATION ±0.5% ±0.3% ±0.2%
SETUP, RISE, HOLD TIME 2s, 50ms, 24ms(only D mode) at full load
INPUTVOLTAGE RANGE B:19 ~ 36VDC C:36 ~ 72VDC D:72 ~ 144VDC or 85 ~ 132VAC
EFFICIENCY (Typ.) 74% 75% 76% 75% 77% 80% 78% 81% 83%
DC CURRENT 4.8A/24V 2.4A/48V 1.8A/96V 4.8A/24V 2.4A/48V 1.8A/96V 4.8A/24V 2.4A/48V 1.8A/96V
INRUSH CURRENT (Typ.) D:18A/96VDC
LEAKAGE CURRENT <0.75mA/120VAC(SD-100D)
PROTECTIONOVERLOAD 105 ~ 135% rated output power
Protection type: Fold back current limiting, recovers automatically after fault condition is removed
OVER VOLTAGE 5.75 ~ 6.75V/10% load 16.8 ~ 20V/10% load 31.5 ~ 37.5V/10% load
Protection type: Hiccup mode, recovers automatically after fault condition is removed
ENVIRONMENTWORKING TEMP. -10 ~ +60ºC (Refer to output load derating curve)
WORKING HUMIDITY 20 ~ 90% RH non-condensing
STORAGE TEMP., HUMIDITY -20 ~ +85ºC ,10 ~ 95% RH
TEMP. COEFFICIENT ±0.03%/ºC (0 ~ 50ºC)
VIBRATION 10 ~ 500Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes
SAFETY & EMC (Note.4)SAFETY STANDARDS Design refer to EN60950-1 CB, TUV
WITHSTAND VOLTAGE I/P-O/P:1.5KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC
ISOLATION RESISTANCE I/P-O/P, I/P-FG, O/P-FG:100M Ohms/500VDC
EMI CONDUCTION & RADIATION Design refer to EN55022(CISPR22) CLASS B
EMS IMMUNITY Design refer to EN61000-4-2,3,4,6,8;ENV50204,EN55024,light industry level,criteria A
OTHERSMTBF 356.7K hrs min.(SD-100B) 355.5K hrs min.(SD-100C) 341.9K Hrs min.(SD-100D) MIL-HDBK-217F (25ºC)
DIMENSION 199*98*38mm (L*W*H)
PACKING 0.65Kg; 20pcs/13.8Kg/0.8CUFT
NOTE 1.All parameters NOT specially mentioned are measured at normal input, rated load and 25ºC of ambient temperature.
2.Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor.
3.Tolerance: includes set up tolerance, line regulation and load regulation.
4.The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives.